Optimal Octagonal Hooked Collar Countermeasure to Reduce Scour Around a Single Bridge Pier

Authors

  • Rashid Farooq
    Affiliation

    Department of Civil Engineering, International Islamic University, Islamabad 44000, Pakistan

    Department of Civil Engineering, Lakehead University, Thunder Bay, ON P7B 5E1, Canada

  • Abdul Razzaq Ghumman
    Affiliation

    College of Engineering, Civil Engineering Department, Qassim University, Al-Mulida 51431, Saudi Arabia

  • Muhammad Atiq Ur Rehman Tariq
    Affiliation

    College of Engineering and Science, Victoria University, P.O. Box 14428, Melbourne, VIC 8001, Australia

  • Afzal Ahmed
    Affiliation

    Department of Civil Engineering, University of Engineering and Technology, Taxila 47080, Pakistan

  • Khan Zaib Jadoon
    Affiliation

    Department of Civil Engineering, International Islamic University, Islamabad 44000, Pakistan

https://doi.org/10.3311/PPci.15966

Abstract

Pier modification countermeasures are essential as they play a vital role in protecting pier against local scour action. Current study investigates experimentally the scour around vertical pier of octagonal cross section with pier modification such as newly proposed octagonal hooked collar is explored, in steady uniform state, under clear water condition. The results of pier scour without any modification were used as a reference to compute the efficiency of hooked collar provision around octagonal pier. The results show that by increasing the hooked collar width up to 2.5 Wp reduced maximum scour depth significantly. However, the experimental investigation revealed that the best combination to be with a hooked collar width of 2.5 Wp, having sidewall height 0.45 Wp. The best combination minimized around 73.3 % of scour hole depth, compared to octagonal pier without any modification. Using experimental results, a new equation is proposed to predict the scour depth around a bridge pier fitted with hooked collar. Moreover, a relation was developed for maximum scour depth and scour hole volume. Results indicate that the scour hole volume around a bridge pier increases quadratically with maximum scour depth.

Keywords:

scour, octagonal, hooked collar, pier shape, scour countermeasure

Published Online

2020-08-05

How to Cite

Farooq, R., Ghumman, A. R., Tariq, M. A. U. R., Ahmed, A., Jadoon, K. Z. “Optimal Octagonal Hooked Collar Countermeasure to Reduce Scour Around a Single Bridge Pier”, Periodica Polytechnica Civil Engineering, 64(4), pp. 1026–1037, 2020. https://doi.org/10.3311/PPci.15966

Issue

Section

Research Article